Service area · Burlington County

Chimney Services in Moorestown, NJ

Moorestown’s housing spans every era from before 1940 to after 2000, by Census estimates. Whatever a house’s age, a fireplace that sits unused is a path for heated air to leave unless its damper seals.

Bright living room with a lit fireplace
On this page
  1. Chimney profile
  2. What the numbers suggest for chimneys in Moorestown
  3. Where the heat goes when the fire is out
  4. Testing your damper's seal
  5. Local questions
  6. Sources

Chimney profile: Moorestown

Census estimates for 8,397 housing units (7,954 occupied).

When homes were built

  • Before 1940 21%
  • 1940–59 18%
  • 1960–79 23%
  • 1980–99 20%
  • 2000 or later 18%

How occupied homes are heated

  • Utility gas 80%
  • Fuel oil 2%
  • Electricity 17%
  • Propane 0%
  • Wood 0%
  • Other or none 1%

Type of housing

  • Single-family, detached 71%
  • Single-family, attached 15%
  • 2–4 units 5%
  • 5+ units 9%

Source: U.S. Census Bureau, American Community Survey 2020–2024 5-year estimates, tables B25034, B25040 and B25024, via Census Reporter. Estimates have margins of error; small categories are approximate.

What the numbers suggest for chimneys in Moorestown

Census estimates count 8,397 housing units in Moorestown, spread almost evenly by era: about 21% from 1939 or earlier, 18% from the 1940s and 1950s, 23% from 1960 to 1979, 20% from the 1980s and 1990s and 18% since 2000. A masonry fireplace normally has its damper at the throat, the narrow opening above the firebox where the Brick Industry Association's construction details seat it, while factory-built fireplaces from later decades follow their maker's design. Both types are pictured in our damper guide.

Utility gas heats about 80% of the township's 7,954 occupied homes, electricity 17% and fuel oil 2%. Central heat carries the load in nearly every household, which leaves the fireplace, in homes that have one, as an occasional extra that stays closed for much of the winter.

About 71% of units are detached houses, 15% attached homes, 5% in small buildings of two to four homes and 9% in larger ones. These township-wide estimates describe housing, not the state of anyone's damper.

Where the heat goes when the fire is out

A chimney is a tall opening to the outdoors, and warm room air rises toward it. The Department of Energy advises keeping the fireplace damper closed unless a fire is burning, because an open damper causes drafts and heat loss in the rest of the house. It also suggests checking the seals around the damper, since a loose seal loses heat through the chimney even when the damper is shut. For a fireplace that is never used, it recommends having the flue plugged and sealed.

CSIA adds the opposite case for tight houses: when the house is short of make-up air, the simplest route for outside air to enter is often down an unused fireplace chimney. Its suggested remedy is a top damper that seals tightly, fitted to whichever fireplace sees the least use and left shut. Either way, heat going up or cold air coming down, the seal at the damper decides how much air moves.

Testing your damper's seal

Do this only with the fireplace cold and the ashes fully out, ideally on a cold, breezy day.

  1. Close the damper fullyNote whether the handle reaches its stop or the plate binds partway.
  2. Feel for airHold the back of your hand or a strip of tissue just inside the opening, near the top. A steady cold draft or a fluttering tissue means air is getting past.
  3. Look up with a flashlightGaps of light around the plate, a warped edge or heavy rust flakes on the hearth point to a damper that no longer seats.

A worn throat damper can sometimes be repaired or replaced from inside the firebox. Another route is a top-sealing damper, which closes against the top of the flue and keeps the whole flue out of the house's air. Both routes are part of our damper repair and replacement work. One exception matters: a fireplace with vented gas logs is not a candidate for closing the damper, since one log maker's manual requires a permanently installed clamp that keeps a minimum opening at all times.

Local questions

Should the damper be closed when the fireplace is not in use?

For a wood-burning fireplace with the fire completely out, yes; the Department of Energy recommends it to cut heat loss. A fireplace with vented gas logs is different, because those log sets require a permanent minimum damper opening.

Can a top-sealing damper replace a broken throat damper?

Often it can, with the old throat plate left open or removed, provided the top of the flue suits the unit. An inspection checks flue size and condition first.

Why does my closed fireplace still feel cold?

A warped plate, a gap at the frame or a worn gasket lets air pass. Air can also come in around a glass door frame or the fireplace surround, so finding where the draft enters comes first.

What if we never use the fireplace at all?

The Department of Energy suggests having the flue plugged and sealed. Our unused-fireplace guide lists the options, including how to leave the flue ready for a future owner who wants a fire.

Sources

  1. U.S. Census Bureau, American Community Survey 2020–2024 5-year estimates (tables B25034, B25040, B25024), via Census Reporter
  2. U.S. Department of Energy, Energy Saver: 5 Ways to Maximize Your Fireplace and Chimney Efficiency
  3. CSIA: Frequently Asked Questions
  4. Brick Industry Association, Technical Note 19A: Residential Fireplaces, Details and Construction (PDF)
  5. Masonry Fireplace Industries Virginiana vented gas log manual